APG ORIGINAL CLAUSE — HANDRAIL-STAINLESS-STAIR-SPEC-R11 / HR-SS-1200-35/GUARDS-RANGE-R3 26October2026.Checked draft only;not NBS-ready/construction/manufacture approval. System Ss_25_60_05_35 Handrail systems,currentofficialtableJuly2026,retrieved26Oct. PublishedAPGbusiness Architectural Products Group Ltd;enquiries@architecturalproducts.uk. Confirm actual manufacturing entity and responsible technical engineer. Product:35DEGREE STAIR stainless wall handrail,1200mm nominal ALONG-RAIL length,35degrees; 42.4mmODx2.0mm tube,75mmcentrestand-off,nominal53.8mmwallclearance, 56.3mmundergrip-to-stem clearance. Study height1000mm is not an approved route height;actualangle/nosingline must be measured. Candidate316Ltube/brackets;actualcertificates/form/consumables/weldability to accept. Two90degree returnedends;source47.5mmCLR elbow geometry is candidate only,match actual fitting grade/wall/geometry/stock before qualified welding. A matching316L2.0mm-wall elbow is NOT established by the inherited stock reference. Wallbrackets ONLY at stations[150.0, 600.0, 1050.0]mm;returnedends carryNOsupportcredit. 25mm stems,coped/welded saddle details and90x10mmwallplates require resistance/WPS/ inspection. Proxy11mmholes,two64mm-pitch LOCAL plate centres (global X/Z projections differ) are not selected anchor design. Survey wall/edges/access/route;design anchors/embedment/plate contact/prying/packing/ cure/torque and review grip/height/clearances/continuity/end treatment/accessibility. Adopt project jurisdiction/use/actions/combinations/deflection/durability basis. Existing3Dbeam sensitivities use idealised joints/roots and member-only selfweight; local tube/saddle/stem/weld/anchor/buckling/contact effects remain. Retain correlated bracket-root force/moment vectors,not independent maxima or individualanchor loads. No guarding/barrier/level/carbon-steel capacity transfer. Obtain competent independent review and agreed representativephysical evidence before final technicalrelease. Specify brushedfinish/grit/direction,passivation/pickling,heat-tint removal,contamination control/isolation/exposure/cleaning,tolerances,accepted drawings, qualified316L material/weld/finishQA and installation method. Nominalmodelmass5.534kg excludes actualanchors/coating/packing;not measuredshippingmass. Handover asbuiltIDs, approved care/inspection and warranty/environmental evidence. No BIM/certifiedrating, origin/stock/leadtime or finalprice established. Geometryunchanged,valueengineeringLATER. See PRODUCT-DATA,GAP-REGISTER,SOURCE-TRACE,FIXING-DEMANDS andexactSTEP.